Truma Ultraheat is the ideal addition to S 3004 and S 5004 heaters in your caravan. Truma Trumatic C Control Panel 34000-59000 [Product Id: 6226] Out of stock. If so which of the coloured cables would we need to attach? Unfollow truma ultraheat to stop getting updates on your eBay Feed. The part no for the maplin relays are N30AW about. No. In my case, I tested the power input to the caravan to confirm that all my relays were working correctly, with the caravan taking the correct amount of current for each heat setting Truma Corp 2800 Harman Dr Elkhart, IN 46514 USA. This works perfectly well and the transformer is a lot easier to get a hold of. When we replaced the pcb we couldnt remember the order of the coloured cables. But if the 240v has failed I would search out the relay. Truma Ultraheat is the ideal addition to S 3004 and S 5004 heaters in your caravan. Sort: Best Match. Is is possible for you to have a look at my pcb if I send it to you before I consider replacing the switch? Phone: +1 (855) 558-7862 Fax: +1 (574) 538-2426. Mar 2, 2017 - Parts for space heating and water heating appliances and control panels Being mechanical it would be more likely to fail than the pcb. Truma Ultraheat Control Panel 30030-98400 - **OBSELTE** [Product Id: 6294] Out of stock. I've changed dozens of relays and not encountered any problems, I've not encountered a faulty switch either, although I've acquired lots of faulty switches from dealers which work fine when I test them?! Truma S Heaters; Truma Ultraheat; Van & Water Combi Heating. The green LED is lit. [Contact Us]
Page 1 In voertuig meenemen! I had them replaced on the board and had hoped this would sort the problem. Please report any error, Caravan Repairs, Servicing and Maintenance. [Event Diary]
For a better experience, please enable JavaScript in your browser before proceeding. We use Royal Mail First Class (non recorded) as a standard return postal service.This has a compensation limit of £46. JavaScript is disabled. Source for Fanmaster mk1 - thermal cut out. Přídavná elektrická spirála Ultraheat se montuje mezi topné těleso a zadní kryt topení. I have a swift challenger and have had some problems with truma ultraheat. Truma Ultraheat. Fiamma VW T5 Bike Racks; Related: truma heater truma ultraheat control truma ultraheat pcb truma ultrastore ultraheat truma heater truma caravan heater truma gas fire truma water heater. In-between seasons you can heat with Truma Ultraheat alone. They have begun to click frantically again and no heat. Brand: Apuljack Engineering; Product Code: AE-P-HE-00012; Availability: 5; £19.08; Ex Tax: £15.90 Got a hold of an old pcb for the truma ultraheat and fitter a 9v transformer as Arc Systems suggested. Truma S 3002 Flue ducting and Installation Box. I only had the relays replaced. £4.76 Off. I've found only relays or the two overtemp stats seem to cause the problems or badly sited remote temperature sensors. I have new stats in stock as well as serviced exchange boards with uprated relays. As suggested, we have since checked the continuity between the black wires and also the blue and green. Please note this is for repair of your board not supply of a new one. I had a look at an element with red cable on one side and green, blue and white on the other. So for anyone coming across a blown transformer in the future fit a 230v - 9v one.-----Ghostpiper Could this mean that the relays are not just fitted correctly as the elements are both ok. Or could it be a combination of faulty switch and relays? Add to cart. Like . All listings - Current page Auction Buy it now Classified Ads. Info £63.82. Unfortunately not! Truma/Carver Remote Control Handset for Original Single Axle Caravan Mover [Product Id: 6340] I really don't know now, you are now saying you replaced the relays and not the whole control board? The original contact material is not much cop to say the least! This seems to eliminate the element. Upgradedreplacement relays for Truma Ultraheat control circuitboard. Not speaking with a lot of knowledge of Truma. They are actually pcb mounted,which the panel behind the fire,are you changing the relays because only 1 element is working? [Virtual Brochure]
Back to the pcb. The relays seem to be working when we first put the pcb back in. If the stats are faulty can they be replaced or do they come as part of the element? Relays not working: My model has settings at 500W, 1KW and 2KW. Info £77.20. You don't say how long since you replaced the board? Carver Truma Operation Video. Not leaving me feedback or giving me anything less in any of the four sections has a great effect on my selling performance . Truma Ultraheat Units. ... Truma Ultraheat; Truma VarioHeat; Fire Type Heaters. Brugsanvisning Side 13 Skal medbringes i køretøjet! In-between seasons you can heat with Truma Ultraheat alone. My very patient and understanding spark has checked over several things but we can't get it going. they don't last that long if in constant use, still, I think one of the thermostats is open circuit and these are replaced individually. Instrucciones de uso Sidan 15 ¡Ilévalas en el vehiculo! Depending on your individual warmth requirements, choose one of three operating levels: 500W, 1000W or 2000W. [Reception]
The new relays seem to be working perfectly ie. The one I fitted was a 2va as opposed to a 1.5va. Info £39.99. The red as said is common, the other colours supply voltage to one element for 1kw, both for 2kw or both in series for 500w. clicking through the different heat settings quietly! Could there be separate fuses for the different settings? Thanks in advance. Really helpful post, thanks Your Truma Ultra heat unit is responsible for the heating of your caravan. These seem fine and therefore eliminates the stats. Depending on your individual warmth requirements, choose one of three operating levels: 500W, 1000W or 2000W. Truma Roof Mounted Air-Conditioning; Under Bench Air-Conditioning. View and Download Truma Ultraheat S 3004 installation instructions manual online. This is no longer the case. When I replace the switch with my own it begins to click frantically and the heater doesn't work. The new relays seem to be working perfectly ie. Time: ending soonest; that would point to the wrong relays being fitted or the correct ones not fitted well? Grove Description 01 30030-98600 Control Ultraheat <04/02 02 10010-78900 Screw B 2.9 x 25 04 30030-98500 898500 Control panel (GB) 05 00000-01000 Screw M 3.5 x 25 UK) 06 00000-11100 Screw cover UK 07 00000-01100 Control knob UK 08a 30030 … I hope this post has been some help if only to point out what could be faulty on the PCB apart from the relays. As you have not got a remote stat fitted, the room stat is in the switch and a poor connection at either end of the loom would get worse as the 'room' gets a little warmer, this then could well make the stat act erratically and switch the relays as yours are doing. It could be mounted on the pcb (box like) or adjacent. Just trying to eliminate the different parts. ex Shipping. I borrowed a pcb from a friends caravan whose heater was working perfectly and it does exactly the same thing. Exploded Diagrams; Sales Information; Instructions; Truma S 3002. In order to post a reply you will need to register, or if already registered please log in here, Free UKCampsite.co.uk Window Sticker - Recommend to Friend, [Message Forums]
Click here to read our updated forum rules. pack of 3 replacement quality relays to repair the common fault on ultraheat circuitboards. Apuljack Truma Ultraheat Relay & Transformer Kit. Info £132.30. Is this relevant or are they both do the same function? Being mechanical it would be more likely to fail than the pcb. The Ultra Heat is equipped with a fan that allows the warm air from the heater to be passed around the caravan via a system of pipes. Truma Spares. Truma No. Top Cover for Truma S3002 fires. [Shop!] Truma Control Panel for C3402, C6002 and Therme [Product Id: 6223] Out of stock. But if the 240v has failed I would search out the relay. The additional electric heater warms motor homes and caravans quickly and reliably. 1 at 125 and 1 at 175, these apparently are some what trickier to replace but come in at less than a tenner each. We also connected a temporary supply to the elements both white and green and they are definately working. Initially he was unsure about the mains power supply to the heater but it is reading 240v so we think its ok. Do you have any suggestions what the problem could be or how we could eliminate the different areas? CCG 21320 Truma Ultraheat Parts List For full list of replacement parts for the Truma Ultraheat heater, click - Spec - Parts for other models are available on request 01926 640489 or email sales@caravanparts.co.uk Upgradedreplacement relays for Truma Ultraheat comes with the controller all leads . Truma Ultraheat PC Board 30030-70900 [Product Id: 6520] Out of stock. The switch would seem to be the only thing left to test maybe it's the connection between? Firstly the main pcb behind the fire has relays which burn out. In both cases I changed the pcb’s for ones with beefier relays from a supplier on ebay. What is the function of these cables? The Truma product range includes heating and air conditioning systems, through to hot water generators and manoeuvring systems for caravans. Nepasuje k topením S3002 K, S5002 K a S5002 do roku 4/98. [Features / Advice]
Any further advice or suggestions would be very much appreciated. Quick View. 4 results for truma ultraheat Save truma ultraheat to get e-mail alerts and updates on your eBay Feed. [Caravan Sites & Camping]
Gas pressure regulators and power supply products round off the extensive product range. Pack of 3 replacement quality relays to repair the common fault on Ultraheat circuitboards. [Tent Reviews], Please note we are not responsible for the content of external sites & any reviews represent the author's personal view only. Not speaking with a lot of knowledge of Truma. Any pictures or diagrams would be helpful. That is they were clicking through the heat settings but the heater only worked for a few minutes. Beyond this, Truma produce the much-loved Powrtouch motor-mover manoeuvring systems for caravans, plus … T5 Bike Racks. We have checked the resistence across each element - green/red which we think is 2 kw was reading 55.3 ohms - white/red which we think is 1 kw was reading 54 ohms. Using my own pcb and loom connection and working switch from my friends caravan, the heater is functioning but only on 1kw. As stated above the relays on the circuit board are of poor quality and often burn out. Initially I thought it was the relays and had them replaced after reading the forum as they were clicking constantly. Fixed cost of £40 + from £6 return p&p (UK) The p&p charge covers the postal return of your PCB. David. clicking through the different heat settings quietly! Black with a hint of brown. As there were 2 black ones we were unsure of where they should go. then they won't last 10 minutes! In the last few years I have repaired my and the brother in laws Truma Ultraheat. Initially the heater did work and then it stopped working. If the relays are faulty, this can reduce the power of the heater. [Competitions]
Ultraheat S 3004 electric heater pdf manual download. As I stated in first posting the initial problem appeared to be the relays as they were clicking a lot. Contact Us The elements are connected between green and red, and white and red, (red being common), around 55 to 58 ohms resistance across each element is correct. Your 'good' board though from your mates van also seems faulty to me, are you sure it works on all setting in his van?? It is a duel fuel unit, this means that it runs on 240v mains electric and gas. Info £119.86. The 3 relays are mounted on a pcb within a grey box at the rear of the fire the ones fitted originaly were rated at 10 amps these contacts burn out but the relay coils still operate.later pcbs from about 2004 were fitted with 16 amp relays. Seems by mention of Maplins this is an old post, but in answer to question indeed I do still offer this service, your best though to contact me by the phone number on my website. It could be mounted on the pcb (box like) or adjacent. The other variable is the temperature dial itself, it's only a simple 'volume' control and this could be dirty inside giving the same results. Truma PRIMA Leisure is a dedicated Truma parts stockist and specialist, stocking a full range of after-market fittings for many of Truma's most popular products. Best Match. I have a swift challenger and have had some problems with truma ultraheat. davemarshall Member Posts: 27 Joined: 2018-05-19 Location: Wigan Auto-Sleeper: Nuevo Vehicle Year: 2006. The general fault is that the UItraheat elements will only work on 500W but not on the higher power settings. Add to Cart. [Company Listings]
by Paulmold on Fri Dec 28, 2018 7:01 am. could well be true?! As yours is still under warranty I would let them sort it for you. Truma S 3002 Flue ducting and Front Case. The relays click a lot and elements heated for a very brief period. Refine. Rapidly turning it a dozen or more times might settle it down and prove where the fault lies? The 3 relays are mounted on a pcb within a grey box at the rear of the fire the ones fitted originaly were rated at 10 amps these contacts burn out but the relay coils still operate.later pcbs from about 2004 were fitted with 16 amp relays. Truma Ultraheat Electric Heater Additional electric heater to heat caravans faster in any weather. Apologies if I gave you the impression I changed the whole board. Součástí základního balení termostat a 3 m kabelu k ovládacímu panelu. The new ones fitted must have the same resistance across the coil as the originals or near as don't matter anyway. [Caravans & Motorhomes For Sale]
I would appeciate any help you can offer. Control panel for Truma S3002 fires. Easier to replace the pcb than the relays individually and costs around £80 Secondly there are 2 thermal cut out sensors. Also for: Ultraheat s … Would it be possible to get a breakdown of the coloured cables and their function. Summary of Contents for Truma Ultraheat Solo. The cause of stat failure I'm told is down to a slightly loose spade connection, loose causes high resistance, resistance causes heat and heat melts the stat! Here at Apuljack Engineering we have repaired countless Truma Ultraheat boards with a variety of fau.. £19.08 Ex Tax: £15.90. Is it possible to test the elements themselves by bypassing the main controls. ... Citroen Jumper/Relay; Mercedes Vito; Peugeot Boxer; VW T5. That's really useful. Re: Truma Ultraheat no green light . but if yours have even worse contact material? more Format Format. Truma 5m Extension Cable for C3402, C4002, C6002 [Product Id: 6219] Out of stock. All of the products in all product areas are among the most high performance in the market. The problem is not the amperage rating but the design of the control, 16A ones then, (of the same type), will at best only last a bit longer than 10A. If so they will work, no need to bypass anything and mess about with mains voltage! Good luck. You must log in or register to reply here. The additional electric heater warms motor homes and caravans quickly and reliably. Initially I thought it was the relays and had them replaced after reading the forum as they were clicking constantly. Sorry for all the questions just trying to get an understanding of the workings of the heater and then hopefully get a solution. Apuljack Truma Ultraheat Relay & Transformer Kit. As the same thing is happening with a second pcb, could it be the control switch or do these ever give any problems. Any tips anyone - my Truma heater is working perfectly well on 500w setting but won't go on either 2kw or 3kw settings which I needed last week! This is generally caused to failure of the original relays going faulty. Produkt pasuje k topením Truma S3004 a S5004, S3002 od roku 81 a novější a S5002 od roku 4/98 a novější. Apuljack Engineering offers this simple repair kit to replace and upgrade the relays and transformer on the Truma Ultraheat main PCB. Trumatic S3002 L P Gas Heater + Ultraheat Spare Parts. The green LED on the control switch is working so the 12v transformer must be ok. First my memory was correct, the second stat is connected to the board between green and blue.